Solis S6-EH1P8K-L-PLUS Hybrid and Single-Phase Inverter
- 10 seconds of 200% overload capability
- Multiple inverters can operate together to form a microgrid
- Generator-compatible to extend backup duration during grid power outage.
- Supports dual backup ports for intelligent control of critical and non-critical loads.
MODEL | S6-EH1P8K-L-PLUS |
---|---|
MAX. DC POWER | 16kW |
MAX. DC VOLTAGE(VDC) | 500 V |
START VOLTAGE | 90 V |
NOMINAL VOLTAGE | 330 V |
MPP VOLTAGE RANGE | 90 – 435 V |
NO. OF MPP TRACKERS | 2 / 4 |
MAX INPUT CURRENT | 32 A / 32 A |
MAX. SHORT-CIRCUIT CURRENT | 40 A / 40 A |
BATTERY TYPE | Li-ion / Lead-acid |
BATTERY VOLTAGE RANGE | 40 – 60 V |
MAX. CHARGE / DISCHARGE POWER | 8 kW |
MAX. CHARGE / DISCHARGE CURRENT | 190 A |
COMMUNICATION | CAN / RS485 |
RATED OUTPUT POWER | 8 kW |
MAX. OUTPUT POWER | 8kVA |
RATED GRID VOLTAGE | L/N/PE 220 V / 230 V |
RATED GRID FREQUENCY | 50 Hz / 60 Hz. |
RATED GRID OUTPUT CURRENT | 36.4 A / 34.8 A |
MAX. OUTPUT CURRENT | 36.4 A / 34.8 A. |
POWER FACTOR | > 0.99 (0.8 leading – 0.8 lagging) |
THDI | <2% |
INPUT VOLTAGE RANGE | 187 – 253 V |
MAX. INPUT CURRENT | 50A |
FREQUENCY RANGE | 45 – 55 Hz / 55 – 65 Hz |
RATED OUTPUT POWER | 8 kW |
MAX. APPARENT OUTPUT POWER | 2 times of rated power, 10 s. |
BACK-UP SWITCH TIME | < 4 ms |
RATED OUTPUT VOLTAGE | L/N/PE, 220 V / 230 V. |
RATED FREQUENCY | 50 Hz / 60 Hz. |
RATED OUTPUT CURRENT | 22.8 A / 21.8 A. |
MAX. AC PASSTHROUGH CURRENT | 40 A. |
THDV (@LINEAR LOAD) | < 2% |
MAX.EFFICIENCY | 96.2% |
EUROPEAN EFFICIENCY | 96.1% |
BAT CHARGED BY PV / AC MAX. EFFICIENCY |
95.3% / 93.9% |
BAT DISCHARGED TO AC MAX. EFFICIENCY | 93.8% |
DC REVERSE POLARITY PROTECTION | yes |
GROUND FAULT MONITORING | yes |
INTEGRATED AFCI 2.0 | Optional |
PROTECTION CLASS / OVER VOLTAGE CATEGORY | I / II (PV and BAT) III (MAINS and BACKUP and GEN). |
DIMENSIONS (W × H × D) | 335 × 560 × 253 mm |
WEIGHT | 23.5 kg |
TOPOLOGY | High frequency isolation (for battery) |
SELF-CONSUMPTION (NIGHT) | < 1 W |
OPERATING AMBIENT TEMPERATURE RANGE | -40 ~ +60°C |
INGRESS PROTECTION | IP66 |
NOISE EMISSION (TYPICAL) | < 60 dB(A) |
COOLING CONCEPT | Intelligent fan-cooling |
MAX. OPERATION ALTITUDE | 3000 m |
SAFETY / EMC STANDARD | IEC/EN 62109-1/-2, EN 61000-6-2/-3. |
DC CONNECTION | MC4 plug (PV port) / Terminal Block (BAT port) |
AC CONNECTION | Terminal Block |
DISPLAY | 7.0″ LCD display & Bluetooth + APP. |
COMMUNICATION | RS485, CAN, Optional: Wi-Fi, GPRS, LAN. |
Grid connection standard